A Randomized Trial of E-Cigarettes versus Nicotine-Replacement Therapy

Date:

E-cigarettes are commonly used in attempts to stop smoking, but evidence is limited regarding their effectiveness as compared with that of nicotine products approved as smoking-cessation treatments.

We randomly assigned adults attending U.K. National Health Service stop-smoking services to either nicotine-replacement products of their choice, including product combinations, provided for up to 3 months, or an e-cigarette starter pack (a second-generation refillable e-cigarette with one bottle of nicotine e-liquid [18 mg per milliliter]), with a recommendation to purchase further e-liquids of the flavor and strength of their choice.

Treatment included weekly behavioral support for at least 4 weeks. The primary outcome was sustained abstinence for 1 year, which was validated biochemically at the final visit. Participants who were lost to follow-up or did not provide biochemical validation were considered to not be abstinent. Secondary outcomes included participant-reported treatment usage and respiratory symptoms.

A total of 886 participants underwent randomization. The 1-year abstinence rate was 18.0% in the e-cigarette group, as compared with 9.9% in the nicotine-replacement group (relative risk, 1.83; 95% confidence interval [CI], 1.30 to 2.58; P<0.001). Among participants with 1-year abstinence, those in the e-cigarette group were more likely than those in the nicotine-replacement group to use their assigned product at 52 weeks (80% [63 of 79 participants] vs. 9% [4 of 44 participants]).

Overall, throat or mouth irritation was reported more frequently in the e-cigarette group (65.3%, vs. 51.2% in the nicotine-replacement group) and nausea more frequently in the nicotine-replacement group (37.9%, vs. 31.3% in the e-cigarette group). The e-cigarette group reported greater declines in the incidence of cough and phlegm production from baseline to 52 weeks than did the nicotine-replacement group (relative risk for cough, 0.8; 95% CI, 0.6 to 0.9; relative risk for phlegm, 0.7; 95% CI, 0.6 to 0.9). There were no significant between-group differences in the incidence of wheezing or shortness of breath.

Read full article here.

Peter Hajek et al. – New England Journal of Medicine – 2019-02-14.

Want More Investigative Content?

Curate RegWatch
Curate RegWatchhttps://regulatorwatch.com
In addition to our original coverage, RegWatch curates top stories on issues and impacts arising from the regulation of economic, social and environmental activity in Canada and the U.S.

LEAVE A REPLY

Please enter your comment!
Please enter your name here

MORE VAPING

Industry Plot? | FDA Commissioner Denigrates Tobacco Harm Reduction | RegWatch

Does the regulator responsible for overseeing tobacco products in the U.S. believe in the practice of tobacco harm reduction? According to FDA Commissioner Robert...

Vaping Coverage Get it NOW!

Sign Up for Incisive Content!

RegWatch original video is designed to move opinion. Get our videos first and be the first to share.

Your Information will never be shared with any third party